XT/XTE Series
Single-Phase Hybrid Inverter
XTE
ON/OFF Grid Hybrid Inverter
with High Power Bypass
North America Version
Technical Data XT – 6K XT – 8K XT – 10K
Solar
Nominal PV Power ( kW ) 6 8 10
Max . Power ( kW ) 9 12 15
Max . PV DC Voltage ( V ) 500 ( 520 )
MPPT Voltage Range ( V ) 110-500
Max . Input Current of Single MPPT ( A ) 14
MPPT Tracker / Strings 4
Channels Per MPPT 1
AC Output
Rated Output Power ( kW ) 6 8 10
Max . AC Output Power ( kW ) 6.6 8.8 11
Max . Output Current ( A ) 27.5 36.7 45.8
AC Output Voltage ( V ) 120/240 ( split phase ) , 208 ( 2/3 phase ) , 230 ( single phase )
Rated Frequency ( Hz ) 50 / 60
Frequency Range 50 + 5 Hz / 60 ± 5 Hz
THDI < 3 %
Battery
Battery Voltage Range ( V ) 40-58.4
Max . Charging Voltage ( V ) 58.4
Max . Charge / Discharge Current ( A ) 135/135 190 / 190 190/210
Battery Type Li – lon
Communication Interface WeCo – CAN
EPS Output
Rated Power ( kVA ) 6 8 10
Rated Output Voltage ( V ) 120/240 ( split phase ) , ( 2/3 phase ) , 230 ( single phase not for UL type )
Rated Output Current ( A ) 25 33.3 41.6
Rated Frequency ( Hz ) 50/60
Automatic Switching Time ( ms ) < 10
THDI < 3 %
Overload Capacity 125 % . 60s / 150 % . Is
General Data
North American Efficiency 297.2 %
Ingress Protection IP65 / NEMA 3R
Noise Emission ( dB ) < 38
Operating Temperature ( ° C ) -25 ° C -60 ° C
Cooling Natural
Safety Standard UL1741, CSA C22.2 No.107.1 : 16 ,UL1998
EMC FCC Part15 , Class B
On – Grid IEEE1547 , CPUC Rule21 , SRD V2.0 , UL1741 SA , UL1741 SB
DC ARC – Fault UL1699B
* Available only in specific States

See warranty for performance warranty applicability.
See Performance Warranty Terms and the Standard Test Conditions “STC”.
All data is subjected to change without prior notice: Always ask WeCo for the most recent datasheet and manual before purchasing.
No part of this document can be copied or reproducted without WeCo written permission.

europe Version
Technical Data XTE – 6K XTE – 8K XTE – 10K
Solar  
Nominal PV Power ( kW ) 6 8 10
Max . Power ( kW ) 9 12 15
Max . PV DC Voltage ( V ) 500 ( 520 )
MPPT Voltage Range ( V ) 110 500
Max . Input Current of Single MPPT ( A ) 14
MPPT Tracker / Strings 4
Channels Per MPPT 1
AC Output  
Rated Output Power ( kW ) 6 8 10
Max . AC Output Power ( kW ) 6.6 8.8 11
Max . Output Current ( A ) 27.5 36.7 45.8
AC Output Voltage ( V ) 230 ( single phase )
Rated Frequency ( Hz ) 50/60
Frequency Range 50 ± 5 Hz / 60 ± 5 Hz
THDI < 3 %
Battery  
Battery Voltage Range ( V ) 40- 58.4
Max . Charging Voltage ( V ) 58.4
Max . Charge / Discharge Current ( A ) 135/135 190/190 190/210
Battery Type Li – Ion
Communication Interface WeCo – CAN
EPS Output  
Rated Power ( kVA ) 6 8 10
Rated Output Voltage ( V ) 230 ( single phase Not for North America Standard )
Rated Output Current ( A ) 25 33.3 41.6
Rated Frequency ( Hz ) 50/60
Automatic Switching Time ( ms ) < 10
THDI < 3 %
Overload Capacity 125 % , 60s / 150 % . Is
General Data  
Europe Efficiency ≥ 98.2 %
Ingress Protection IP65 / NEMA 3R
Noise Emission [ dB ] < 38
Operating Temperature ( ° C ) – 25 ° C -60 ° C
Cooling Natural
Relative Humidity 0-95 % ( non – condensing )
Altitude 2.000m ( above 2000m derating )
Dimensions ( W x D x H ) ( mm ) 430 × 225 * 710
Weight ( kg ) 41
Isolation Transformer No
Self – Consumption ( W ) < 3
Display  
Logic Multicolor LED Bar LED BAR
COMM 1 WeCo WiFi Antenna
COMM 2 CAN
Safety Standard  
EUROPE + SOUTH AFRICA EMC / CE / IEC 61000 : 4/3
IEC62109
NRS 097-2-1
Ask your distributor for specific Certifications Available
* Available only in specific States

See warranty for performance warranty applicability.
See Performance Warranty Terms and the Standard Test Conditions “STC”.
All data is subjected to change without prior notice: Always ask WeCo for the most recent datasheet and manual before purchasing.
No part of this document can be copied or reproducted without WeCo written permission.

Sign up to receive the WeCo
Technical Newsletter.

Keep up to date with the latest insights, news, training events, and exclusive content from WeCo, direct to your inbox